Read the bench tape before you ever upload a photo.

The intake column below is the prefilled symptom — what a tech rolling up to this furnace would tap in on the truck. The right column is what the engine returns: ranked probable causes, a parts cross-reference, and a numbered procedure the tech can run start to finish.

Prefilled intake and ranked probable causes

INTAKE
// pre-loaded · read-only
What the tech wrote up.
The same five inputs the live form collects — locked here so you can read along.

Photo

attached · ir-led-receipt.jpg

Voice note

none

// engine v1 · static scenario · result pre-loaded

RANKED
// top 3 of seed
Probable causes, in order.
Each card shows the confidence the engine placed on this fault.
01
HVAC

Blower motor failure

confidence
100%

No airflow at the supply registers; motor is hot, surging, or completely dead.

remedyPull the blower door, watch the module for flashing LEDs, then bench-test the motor windings.
02
HVAC

Low refrigerant charge

confidence
68%

Suction line ices, delta-T collapses at the return, and superheat climbs above design.

remedyRecover the remaining charge, leak-search at the evaporator and line set, then weigh in by spec.
03
HVAC

Bad run/start capacitor

confidence
42%

Outdoor fan hums but does not spin, or hard-starts under load; microfarads drift from nameplate.

remedyDischarge safely, measure MFD against rating (±5%); replace both caps if dual-rated.

Parts cross-reference and repair procedure

PARTS
// 4 stock-or-replace · top-ranked cause
Cross-reference parts the truck should be carrying.
Anchored to the top-ranked cause’s remedy. The bench updates this list once a real run completes.
SKUPartSource
MTR-2.0-VARECM blower motor assemblytop-ranked cause · replacement
CAP-45/5-DUALDual run capacitor 45/5 µFmatch #3 · verify MFD on bench
WHL-10X8-CWBlower wheel 10"×8" CWtop-ranked cause · paired swap
R410A-25LBR-410A refrigerant · 25 lbmatch #2 · recover before adding

// derived from top cause remedy · bench updates post-escalation

PROCEDURE
// ordered · fault-code → fix
Step-by-step repair procedure.
Read off the bench tape the same way a tech would walk through it.
  1. 01

    Stage

    Read the board

    Confirm the E3 cutout on the diagnostic LED sequence and note any co-thrown codes (E4, A5) before touching the refrigerant side.

  2. 02

    Stage

    Static pressure check

    Pull the blower door and measure both sides of the heat exchanger against spec — a tripping pressure switch often points at a restricted return before it ever points at a refrigerant issue.

  3. 03

    Stage

    Leak search

    Inspect the evaporator coil and line set with an electronic leak detector. Photograph any pinpoint leak for the warranty file before recovering charge.

  4. 04

    Stage

    Weigh in charge

    Recover by weight, repair the leak, then weigh in to the nameplate spec — never top off by suction pressure alone. Verify superheat and subcooling at the return before releasing the system.

// Take it for a spin

Run your own diagnostic — or talk to an owner first.

The intake form takes a symptom, an optional fault code, and any attachments you already have on the truck. Or drop a setup brief and an owner reads it before the first call.

Run your own diagnosticTalk to an owner

// 4 fields · owner reads every one